bcm-v4

[Specification

  1. Back up the Power Dynamic Control value from OFDM Table 0xE, offset 0x12

  2. Set the Power Dynamic Control value in OFDM Table 0xE, offset 0x12 to 7

  3. Set OFDM Table 0xF, offset 0x7 to 0

  4. Perform an OFDM Dummy Transmission

  5. Restore the Power Dynamic Control value to OFDM Table 0xE, offset 0x12