LP PHY Set TX Filter BW(u16 bw)

(bw == bandwidth)

  1. If PHY revision is less than 2
    1. Return immediately
  2. MaskSet PHY Register 0x4EA with mask 0xFFF8 and set with "bw"

  3. MaskSet PHY Register 0x4EB with mask 0xFFF8 and set with "bw"

  4. If bw is less than 2
    1. The DAC setting is 0xE
  5. Otherwise if bw is less than 4
    1. The DAC setting is 0x13
  6. Otherwise
    1. The DAC setting is 0x27
  7. MaskSet PHY Register 0x119 with mask 0xFFE0 and set with the DAC setting

.