Generate the TSSI Table
TX PA Value, CG, Target TSSI Value, TX Power Value
A/G PHYs
- Conditional
- If the passed in Idle TSSI value is 3 or greater
- Use the passed in Idle TSSI value as the Target Idle TSSI value
- Otherwise
- Use 0x3E as the Target Idle TSSI Value
- CONTINUES...
- If the passed in Idle TSSI value is 3 or greater
G PHY Only
- Set the Target Idle TSSI value to 0x34
- Use the Fixed GPHY TSSI to DBM table
Fixed GPHY TSSI to DBM Table
TSSI value |
dBm (in Q5.2) |
0 |
77 |
1 |
77 |
2 |
77 |
3 |
76 |
4 |
76 |
5 |
76 |
6 |
75 |
7 |
75 |
8 |
74 |
9 |
74 |
10 |
73 |
11 |
73 |
12 |
73 |
13 |
72 |
14 |
72 |
15 |
71 |
16 |
71 |
17 |
70 |
18 |
70 |
19 |
69 |
20 |
68 |
21 |
68 |
22 |
67 |
23 |
67 |
24 |
66 |
25 |
65 |
26 |
65 |
27 |
64 |
28 |
63 |
29 |
63 |
30 |
62 |
31 |
61 |
32 |
60 |
33 |
59 |
34 |
58 |
35 |
57 |
36 |
56 |
37 |
55 |
38 |
54 |
39 |
53 |
40 |
52 |
41 |
50 |
42 |
49 |
43 |
47 |
44 |
45 |
45 |
43 |
46 |
40 |
47 |
37 |
48 |
33 |
49 |
28 |
50 |
22 |
51 |
14 |
52 |
5 |
53 |
-7 |
54 |
-20 |
55 |
-20 |
56 |
-20 |
57 |
-20 |
58 |
-20 |
59 |
-20 |
60 |
-20 |
61 |
-20 |
62 |
-20 |
63 |
-20 |