bcm-v4

[Specification

Generate the TSSI Table

TX PA Value, CG, Target TSSI Value, TX Power Value

A/G PHYs

  1. Conditional
    1. If the passed in Idle TSSI value is 3 or greater
      1. Use the passed in Idle TSSI value as the Target Idle TSSI value
    2. Otherwise
      1. Use 0x3E as the Target Idle TSSI Value
    3. CONTINUES...

G PHY Only

  1. Set the Target Idle TSSI value to 0x34
  2. Use the Fixed GPHY TSSI to DBM table

Fixed GPHY TSSI to DBM Table

TSSI value

dBm (in Q5.2)

0

77

1

77

2

77

3

76

4

76

5

76

6

75

7

75

8

74

9

74

10

73

11

73

12

73

13

72

14

72

15

71

16

71

17

70

18

70

19

69

20

68

21

68

22

67

23

67

24

66

25

65

26

65

27

64

28

63

29

63

30

62

31

61

32

60

33

59

34

58

35

57

36

56

37

55

38

54

39

53

40

52

41

50

42

49

43

47

44

45

45

43

46

40

47

37

48

33

49

28

50

22

51

14

52

5

53

-7

54

-20

55

-20

56

-20

57

-20

58

-20

59

-20

60

-20

61

-20

62

-20

63

-20


Exported/Archived from the wiki to HTML on 2016-10-27