bcm-v4

[Specification

Uploading the Table

  1. Loop 32 times, from 0 to 31
    1. Write the Generated TSSI Table Value corresponding to the loop index to the OFDM table 0x15 with offset corresponding to the loop index + 32

  2. Loop 32 times, from 32 to 63
    1. Write the Generated TSSI Table Value corresponding to the loop index to the OFDM table 0x15 with offset corresponding to the loop index - 32

  3. Write the 64 Generated TSSI Table Values to the B PHY Registers 0x380 - 0x39F, taking two bytes of the table together as a little endian value


Exported/Archived from the wiki to HTML on 2016-10-27